Place of Origin:
China
Brand Name:
ZEROONE-Control
Certification:
CE ROHS
Model Number:
DM556 / P2405D
Document:
| Output Peak Current | Output Mean Current | SW1 | SW2 | SW3 | Current Setting Description |
|---|---|---|---|---|---|
| Default[1.0A] | on | on | on | When SW1, SW2 and SW3 are set to on on on, the required current can be set by PC software, with a maximum value of 5.6A and a resolution of 0.1A. If not set, the default current is 1.4A. | |
| 2.1A | 1.5A | off | on | on | |
| 2.7A | 1.9A | on | off | on | |
| 3.2A | 2.3A | off | off | on | |
| 3.8A | 2.7A | on | on | off | |
| 4.3A | 3.1A | off | on | off | |
| 4.9A | 3.5A | on | off | off | |
| 5.6A | 4.0A | off | off | off |
| Steps/Revolutions | SW5 | SW6 | SW7 | SW8 | Subdivision Description |
|---|---|---|---|---|---|
| Default[3600] | on | on | on | on | When SW5, SW6, SW7 and SW8 are all on, the driver subdivision adopts the default driver subdivision: the user can set the subdivision through PC software, and the minimum value is 1, and the resolution is 1, and the maximum value is 51200. |
| 400 | off | on | on | on | |
| 800 | on | off | on | on | |
| 1600 | off | off | on | on | |
| 3200 | on | on | off | on | |
| 6400 | off | on | off | on | |
| 12800 | on | off | off | on | |
| 25600 | off | off | off | on | |
| 1000 | on | on | on | off | |
| 2000 | off | on | on | off | |
| 4000 | on | off | on | off | |
| 5000 | off | off | on | off | |
| 8000 | on | on | off | off | |
| 10000 | off | on | off | off | |
| 20000 | on | off | off | off | |
| 25000 | off | off | off | off |
| Parameter | Minimum | Typical | Maximum | Unit |
|---|---|---|---|---|
| Output Current | 0.1 | - | 5.6 | A |
| Input Power Supply Voltage | 24 | 36 | 50 | VDC |
| Control Signal Input Current | 6 | 10 | 16 | mA |
| Control Signal Interface Level | 4.5 | 5 | 28 | Vdc |
| Minimum Pulse Width | 1.5 | - | - | us |
| Step Pulse Frequency | 0 | - | 200 | KHz |
| Insulation Resistance | 500 | MΩ |
| Cooling Method | Natural cooling or forced air cooling |
| Service Environment | Should not be placed near other heating equipment, avoid dust, oil mist, corrosive gas, excessive humidity and strong vibration. Prohibit presence of flammable gas and conductive dust. |
| Operating Temperature | -5℃ to +50℃ |
| Humidity | 40-90%RH |
| Vibration | 5.9m/s² MAX |
| Storage Temperature | -20℃ to 80℃ |
| Use Altitude | Below 1000 meters |
| Weight | Approximately 250 grams |
Send your inquiry directly to us